Searching for workable clues to ace the Cisco 300-615 Exam? You’re on the right place! ExamCert has realistic, trusted and authentic exam prep tools to help you achieve your desired credential. ExamCert’s 300-615 PDF Study Guide, Testing Engine and Exam Dumps follow a reliable exam preparation strategy, providing you the most relevant and updated study material that is crafted in an easy to learn format of questions and answers. ExamCert’s study tools aim at simplifying all complex and confusing concepts of the exam and introduce you to the real exam scenario and practice it with the help of its testing engine and real exam dumps

Go to page:
Question # 49

Refer to the exhibit The EEM applet must generate a syslog message whena BGP adjacency flaps. This message must be displayed to the console of the switch. However, when a BGP adjacency failure is simulated, no syslog message is displayed. Which action resolves the issue?

A.

Add the event-default action statement.

B.

Modify the policy to use the snmp trap action.

C.

Adjust the policy to match an SNMP OID.

D.

Set the logging priority to Wamings.

Full Access
Question # 50

A vPC Type-1 inconsistency between two vPC peers in a VXLAN EVPN setup is discovered. Which two actions need to be attempted to resolve the issue? (Choose two.)

A.

Configure the NVE interfaces to be Up on both switches.

B.

Set a different distributed gateway virtual MAC address.

C.

Set a different secondary IP addresses on NVE source-interface.

D.

Configure the same VNI to multicast group mapping.

E.

Set a different primary IP addresses on NVE source-interface.

Full Access
Question # 51

Refer to the exhibit.

The FCoE traffic fails to traverse the vfc2 interface. The VSAN 102 is configured for vfc2. Which action resolves the issue?

A.

Enable LLDP on the interface vfc2

B.

Activate DCBX on the N9K switch

C.

Activate DCBX on the interface e101/1/2

D.

Enable LLDP on the neighbor switch

Full Access
Question # 52

Refer to the exhibit.

All servers that must boot from the network fail to receive their DHCP addresses and download the configuration. After close examination, an engineer discovers that all interfaces connected to the affected servers are down with the message " No LACP PDU. " Which command set resolves the issue?

A.

int eth1/2

lacp port-priority 1

B.

int po13

no lacp suspend-individual

C.

interface po13

no lacp graceful-convergence

D.

int eth1/2

lacp rate fast

Full Access
Question # 53

A Cisco Nexus 9000 Series Switch crashes and fails to boot. An engineer must recover the switch and investigate the issue. The switch uses 172.20.50.213/24 IP address for management and its default gateway is 172.20.50.254. Drag and drop the steps for recovering the Cisco Nexus 9000 Series Switch from the left onto the right. Not all steps are used.

Select and Place:

Full Access
Question # 54

A firmware upgrade on a fabric interconnect fails. A bootflash contains a valid image. Drag and drop the recovery steps from the left onto the correct order on the right.

Full Access
Question # 55

Refer to the exhibit. An engineer deploys a Cisco MDS 9000 Series Switch in a SAN. N9K-1 fails to learn the target WWNs and the interface fc1/4 fails to operate. The engineer collected this information about the environment:

MDS-A is configured as an NPV switch.

The WWNs of the storage array are present in the FLOGI database of MDS-A.

Interfaces fc1/3 and fc1/4 on MDS-A and N9K-1 are enabled.

Which set of actions resolves the issue?

A.

Assign fc1/3 as NP port on MDS-A and F port on fc1/4 N9K-1.

B.

Configure F port on MDS-A fc1/3 and N9K-1 fc1/4.

C.

On N9K-1, define fc1/4 as a trunk port and F port mode.

D.

Set 0x000001 FCID on N9K-1 and reset interface fc1/4.

Full Access
Question # 56

An engineer upgrades Cisco UCS firmware from release 3. 1(2) to release 3. 1(3) using Auto Install. Both fabric interconnects go offline during the software upgrade installation and issue multiple F SM retries in the DeployPollActivate stage. Which set of actions resolves the issue?

A.

Fix the rights to 666 with the debug plugin on the primary fabric interconnet Save the current configuration on the running fabric interconnect.

Continue the upgrade on both fabric interconnects.

B.

Enable the management interface monitoring policy on the fabric interconnects. Initiate a configuration backup on both fabric interconnects.

Commit the pending fabric interconnect reboot activity.

C.

Acknowledge the error and reboot the primary fabric interconnect. Clear the default firmware version and upload a new one.

Restart the upgrade process manually.

D.

Clear the startup version of the default infrastructure and server pack. Remove the service pack from the subordinate node.

Upgrade with the Force attribute through Auto Install.

Full Access