Summer Certification Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

OmniStudio-Developer Exam Dumps - Salesforce Certified OmniStudio Developer Plat-Dev-210

Searching for workable clues to ace the Salesforce OmniStudio-Developer Exam? You’re on the right place! ExamCert has realistic, trusted and authentic exam prep tools to help you achieve your desired credential. ExamCert’s OmniStudio-Developer PDF Study Guide, Testing Engine and Exam Dumps follow a reliable exam preparation strategy, providing you the most relevant and updated study material that is crafted in an easy to learn format of questions and answers. ExamCert’s study tools aim at simplifying all complex and confusing concepts of the exam and introduce you to the real exam scenario and practice it with the help of its testing engine and real exam dumps

Go to page:
Question # 9

A customer sets up to LWC Omniscripts, one embedded into another. Account is set in a Set Values element in the parent Omniscript.

The AccountId set in the parent Omniscript is used to another Set Values element ContextAccountid in the embedded OmniScript. The embedded Omniscript is activated.

While previewing the OmniScript flow from the parent, it is found that Account is set correctly in the parent OmniScript. However. ContextAccountId in the embedded OmniScript is not set with the AccountId from parent Omniscript. On previewing the embedded OmniScript individually, it is found that ContextAccountId is set correctly.

What is the reason for this? Refer to the exhibit below.

A.

Both parent and embedded OmniScripts have the same element name for the Set values element.

B.

A developer failed to include a Navigation Element to pass data from the parent OmniScript.

C.

The LWC PubSub Message flag in the Set Values action of the parent has not been set.

D.

The flag pass Data JSON in the parent OmniScript in not configured correctly.

Full Access
Question # 10

A developer configures a FlexCard with a Data Mapper data source that uses the params.id as an input. When the developer clicks " View Data " on the FlexCard, valid data displays. However, when the developer previews the layout, the FlexCard does not display.

What could cause this error?

Choose 2 answers

A.

The RecordId in the Test Data Source Settings is for the wrong record type.

B.

There is no Salesforce record for the FlexCard based on the RecordId in the layout ' s Test Data Source Settings.

C.

The Data Node field for the FlexCard is empty.

D.

The Attributes haven ' t been configured to pass the data to the fields.

Full Access
Question # 11

A developer is creating a FlexCard and needs to display additional information using a Flyout.

Which two types of components can the developer embed in the flyout?

Choose 2 answer

A.

An OmniScript

B.

An Integration Procedure

C.

A DataRaptor

D.

A Child FlexCard

Full Access
Question # 12

No More Homelessness, a nonprofit organization, needs to implement a solution for its case managers to quickly view an applicant ' s pending service requests, which are stored in both Salesforce Contact records and an external grant management database. The solution must display the data consistently without requiring the case manager to navigate away from the Contact record.

Which OmniStudio tool should the OmniStudio Developer use to retrieve and display the combined data in a single, focused view on the Contact record page?

A.

Data Mapper Transform

B.

Calculation Procedure

C.

OmniScript

D.

FlexCard

Full Access
Question # 13

A developer builds a new OmniScript. It contains aSet Values element with a ContextId key/value pair that was used during testing.

What should the developer do before moving the OmniScript to a production org?

A.

Update the ContextId value to specify an id from the Production org.

B.

Add a Show/Hide condition on the Set Values element.

C.

Delete or Deactivate the Set Values element.

D.

Deactivate the contextId key/value pair

Full Access
Question # 14

Universal Containers needs to change the labels on the navigation buttons at the bottom of its OmniScript. Specifically, Universal Containers wants to change the Next button to display Continue.

Where should the OmniStudio Developer make this change?

A.

In the Element Name and Label mapping in the OmniScript Setup tab

B.

In the LWC Component Override property of the OmniScript Setup tab

C.

In the properties of each individual Step element

D.

In the properties of the Navigate Action element

Full Access
Question # 15

An OmniStudio Developer is designing an OmniScript to be embedded in a website with specific mobile responsiveness requirements. To ensure input fields adjust correctly on smaller screens, which OmniStudio feature should the developer rely on?

A.

Using a Custom Lightning web component for the entire layout.

B.

Manually setting the Width property for each field.

C.

Relying on the standard OmniScript Responsive Layout provided by the framework.

D.

Applying a Custom CSS Class that uses media queries.

Full Access
Question # 16

A developer is building an OmniScript and needs to retrieve data from a single field in aSalesforce record.

Which OmniScript element does this?

A.

Lookup

B.

Select

C.

HTTP Action

D.

DataRaptor Post Action

Full Access
Go to page: