Labour Day Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

NS0-162 Exam Dumps - NetApp Certified Data Administrator (ONTAP)

Question # 4

A user wants existing data in a FlexVol created in ONTAP 9.1 to be placed into a FlexGroup volume with ONTAP 9.8. In this scenario, which two statements are true? (Choose two.)

A.

Use XCP to copy data from a FlexVol to a FlexGroup.

B.

Use SnapMirror to replicate data from FlexVol to FlexGroup.

C.

You can convert the FlexVol volume to a FlexGroup volume.

D.

A FlexVol to FlexGroup conversion is not supported.

Full Access
Question # 5

Exhibit.

A user cannot save a file on an ONTAP SMB share.

Referring to the exhibit, which action allows the user to save the file?

A.

Allow the file type, file In the CIFS Server policy.

B.

Let the user save the file to a writeable location.

C.

Synchronize the ONTAP Cluster time to the Active Directory time.

D.

Set the user permission for the share to write.

Full Access
Question # 6

After attempting to perform an ONTAP upgrade. It falls during the pre-check. In this scenario, what would cause this problem?

A.

encrypted volumes

B.

offline volume

C.

Idle SnapMirrors

D.

offline data LIF

Full Access
Question # 7

You have deployed an ONTAP C190 cluster enabled with the iSCSI protocol. Your manager asks for available options to protect the data on your cluster using the native SnapMirror technology.

In this scenario, which two products would satisfy this request? (Choose two.)

A.

ONTAP Select

B.

Cloud Volumes ONTAP

C.

Cloud Volumes Service for AWS

D.

Azure NetApp Files

Full Access
Question # 8

You are the administrator of an ONTAP 9.8 cluster. Your company wants to know how many files are In the NAS volumes of the cluster and how old these files are.

Which two tools fulfill this requirement? (Choose two.)

A.

Active IQ Config Advisor

B.

Active IQ Unified Manager

C.

ONTAP System Manager

D.

ONTAP CLI

Full Access
Question # 9

You have finished deploying a NetApp AFF A400 cluster.

Before you place the array into production, which two tools should be used to validate the deployment? (Choose two.)

A.

OnCommand Workflow Automation

B.

Active IQ Unified Manager

C.

Active IQ Config Advisor

D.

Active IQ Web site

Full Access
Question # 10

Exhibit

You have a 4-node cluster.

How many ISCSI LIFs will be created from the SVM setup wizard, as shown in the exhibit?

A.

8

B.

6

C.

16

D.

2

Full Access
Question # 11

Exhibit.

You create a storage virtual machine (SVM) called SVM500 that is provisioned for iSCSI. After creating a LUN in the SVM and mapping it to an igroup, the attached VMware hosts are unable to mount the LUN.

Referring to the exhibit, what is the issue?

A.

The igroup contains the wrong protocol.

B.

The igroup contains multiple Initiators.

C.

The initiator is a member of igroups of different OS types.

D.

The igroup does not contain the appropriate initiators.

Full Access
Question # 12

A node fails on an HA configuration. A successful failover occurs, but your clients that are using the SMB protocol complain that they are not able to access their data.

In this scenario, what caused the problem?

A.

The surviving node is not licensed for CIFS.

B.

One of the cluster Interconnect ports on the surviving node failed.

C.

The quota for the qtree has been reached.

D.

The disk ownership did not transfer correctly.

Full Access
Question # 13

You have created a new FlexCache cache volume and want to warm the cache before clients access the cache volume for the first time. In this scenario, how would you accomplish this task?

A.

Prepopulate the cache volume with data from the origin volume using the flexcache prepopulate start command.

B.

Enable block-level Invalidation using the volume flexcache origin config modify command.

C.

Copy the data from the origin volume to the cache volume with the NetApp XCP Migration Tool.

D.

Synchronize the origin and cache first with the volume flexcache sync-properties command.

Full Access
Question # 14

Exhibit

You have a 4-node ONTAP cluster and use FCP to access several LUNs. You perform a volume move to move a LUN (/vol/sql01_sysdb/lun) from node na01-01 to na01-03. After the move, you perform an HBA rescan from the host, but ALUA Is now seeing twice the number of paths to the LUN.

Referring to the exhibit, which action would solve the problem?

A.

Update the Selective LUN Map configuration for the LUN mapping.

B.

Change the MPIO policy on the host.

C.

Ensure that the fabric zoning is correct.

D.

Reboot the host.

Full Access
Question # 15

Your company runs a NetApp AFF A220 cluster as a file server for NFS and SMB. You want to use one of the unused ports to connect a single Windows host directly, using FC. You have converted the UTA2 ports e0e and e0f to FC and equipped them with a 16-Gbps FC transceiver. Your Windows host fails to connect to the storage.

In this scenario, which action solves the problem?

A.

Use an FC switch between storage and host.

B.

Use the arbitrated loop topology on storage and host.

C.

Use the point-to-point topology on all ports.

D.

Use an Ethernet switch between storage and host.

Full Access
Question # 16

Exhibit.

You have a 2-node NetApp FAS2750 ONTAP cluster. You create a new 20-GB LUN In a new 100-GB volume and write 10 GB of data to the LUN. No storage efficiencies are enabled for the volume or aggregate.

Referring to the exhibit, which two statements are true? (Choose two.)

A.

ONTAP reports that the volume Is using 10 GB of Its containing aggregate.

B.

ONTAP reports the volume as 20% full.

C.

ONTAP reports that the volume Is using 100 GB of its containing aggregate.

D.

ONTAP reports the volume as 10% full.

Full Access
Question # 17

Exhibit.

You have received an alert from Active IQ Unified Manager that interface eOc has gone offline. Network engineering asks for the corresponding MAC address for the port that has a problem.

Referring to the exhibit, which MAC address would you supply to the engineering team?

A.

02:a0:98:fl:2e:be

B.

00:a0:98:fl:2e:b2

C.

00:a0:98:fl:2e:b3

D.

02:a0:98:fl:21:88

Full Access
Question # 18

You have a 50 TO FlexGroup volume that is serving NFSv3 on a FAS8300 HA pair that Is running ONTAP 9.8 software of files. A Linux du command runs for days to count files.

In this scenario, which native ONTAP feature will report real-time file counts?

A.

Quality of Service

B.

Logical Space Reporting

C.

volume autosize

D.

File System Analytics

Full Access
Question # 19

Your company has purchased two NetApp AFF A400 HA pairs. During deployment, how many root aggregates are created?

A.

6

B.

4

C.

2

D.

8

Full Access
Question # 20

You are asked to create a data LIF to allow object storage access to a bucket that is hosted in ON TAP software. In this scenario, which service is required for the LIFs service data policy?

A.

management-HTTPS

B.

data-S3-server

C.

management-BGP

D.

cluster-core

Full Access
Question # 21

Which command parameter will result in a thin-provisioned LUN?

A.

-space-allocation enabled

B.

-space-reservation disabled

C.

-space-gurantee none

D.

-space-guarantee volume

Full Access
Question # 22

You have two ONTAP clusters and are setting up a new SnapMirror SVM replication (SVM DR) relationship. Which two statements are true in this scenario? (Choose two.)

A.

The target SVM subtype must be dp-destination.

B.

The source SVM subtype must be default.

C.

The target SVM subtype must be sync-destination.

D.

The source SVM subtype must be sync-source.

Full Access
Question # 23

Click the Exhibit button.

A company has three servers that are using the iSCSI protocol to connect to a 2 node NetApp ONTAP cluster. The server administrator notices that half of the paths are down. When you check the ONTAP cluster, you notice that the servers are togging into only the first controller.

Referring to the exhibit, which two steps do you take to troubleshoot the issue? (Choose two.)

A.

Verify that the UFs are up.

B.

Verify that the ISCSI data protocol has been enabled on the ports.

C.

Verify that each server has been rebooted.

D.

Verify that the controller has not been taken over.

Full Access
Question # 24

You need to configure data-at-rest encryption for your NetApp ONTAP 9.8 cluster. Your company does not have Key Management Interoperability Protocol (KMIP) services available but must require a passphrase to be entered when a node Is rebooted.

In this scenario, which two actions should be performed to satisfy these requirements? (Choose two.)

A.

Configure an external key management server.

B.

Enable onboard key management.

C.

Enable cluster-wide FlPS-compliant mode.

D.

Enable common criteria mode.

Full Access
Question # 25

Click the Exhibit button.

You have an AFF A400 HA pair serving SMB locally and a FAS8300 HA pair serving SMB over FlexCache Both clusters are running ONTAP 9.8 software.

In this scenario, which two protocol features are supported at the remote cache? (Choose two.)

A.

multiprotocol NFSv4.1

B.

file locking

C.

multiprotocol NFSv3

D.

SMB3 continuously available (CA) shares

Full Access
Question # 26

Windows 2019 reports 500 GB of free space on a disk; however, on the storage side, the LUN has 0 bytes free. When the host deletes files on the disk, auto reclaim on the thin-provisioned LUN does not occur.

In this scenario, which action should you take to enable space reclamation?

A.

Set the space allocation option to disable.

B.

Set the space allocation option to enable.

C.

Enable space guarantees on the volume.

D.

Enable space guarantees on the LUN.

Full Access