Searching for workable clues to ace the Netapp NS0-094 Exam? You’re on the right place! ExamCert has realistic, trusted and authentic exam prep tools to help you achieve your desired credential. ExamCert’s NS0-094 PDF Study Guide, Testing Engine and Exam Dumps follow a reliable exam preparation strategy, providing you the most relevant and updated study material that is crafted in an easy to learn format of questions and answers. ExamCert’s study tools aim at simplifying all complex and confusing concepts of the exam and introduce you to the real exam scenario and practice it with the help of its testing engine and real exam dumps

Go to page:
Question # 17

Where is a kernel core file stored on a FAS9000 system that is running ONTAP 9.12.1 software?

A.

on the partner root aggregate

B.

on the root aggregate

C.

on the mailbox disk

D.

on the boot device

Full Access
Question # 18

You are using wafliron on an aggregate named homedir on a production system.

When is the data on homedir available?

A.

when the administrator manually onlines the aggregate

B.

when wafliron is started

C.

after Phase 4 of wafliron is complete

D.

after the mounting phase of wafliron is complete

Full Access
Question # 19

Which two steps are required to replace a drawer in a DS460c shelf? (Choose two.)

A.

Shut down both nodes.

B.

Disconnect the cable chains from the chassis.

C.

Power off the shelf.

D.

Evacuate all drives in the drawer.

Full Access
Question # 20

What happens when the command diskcopy is run from nodeshell?

A.

It pre-fails a drive in an aggregate and copies it to a spare.

B.

It performs a low-level copy of the disk to another disk.

C.

It copies the disk content to a specified volume.

D.

It triggers a RAID reconstruction of that disk.

Full Access
Question # 21

What is the recommended value for disk and CPU use when you plan an upgrade?

A.

less than 50%

B.

less than 90%

C.

less than 85%

D.

less than 70%

Full Access
Question # 22

During a new SVM deployment, all of the FC LIFs are showing an admin/oper status of up/down. The LIF extended status is Waiting for Link.

What is causing this status?

A.

The FC cables are bad.

B.

The sync-destination LIF is in switchover state.

C.

NPIV is disabled on the switch.

D.

The switch fabric is not configured.

Full Access
Question # 23

Which command can you use to confirm successful completion of an ONTAP upgrade?

A.

system controller sp upgrade show

B.

cluster image show-update-progress

C.

job show –jobtype upgrade

D.

system node upgrade-revert upgrade-task –node < nodename > –version < ontap Version >

Full Access
Question # 24

You receive the following AutoSupport message:

[Node-01: cshmd: hm.alert.raised:alert]:

Alert Id = ClusterSwitchConnectivity_Alert

Alerting Resource = Node-02

raised by monitor ethernet-switch

[Node-01: mgwd: callhome.hm.alert.major:alert]:

Call home for Health Monitor process cshm:

ClusterSwitchConnectivity_Alert[Node-02].

[Node-01: mgwd: callhome.hm.alert.major:alert]:

Call home for Health Monitor process cshm:

ClusterSwitchConnectivity_Alert[Node-02].

When researching, you discover the following output:

Exhibit 2 — Network Port Health

Cluster::* > network port show

-health-status degraded

-fields health-degraded-reasons

node port health-degraded-reasons

-------- ---- -----------------------

Node-02 e0a link_flapping

What action do you take to resolve this issue?

A.

Replace the SFP on port e0a on node-02.

B.

Update the RCF file on the cluster switches.

C.

Update the firmware on the cluster switches.

D.

Replace the SFP on port e0a on node-01.

Full Access