Question # 9

On a single node, one or more interfaces are showing an “unknown” status. What is the best way to resolve the issue?

A.

Change node's polling method to ICMP.

B.

Delete and rediscover the node showing affected interfaces.

C.

Delete and re-add the affected interfaces.

D.

Verify the interfaces are assigned to SolarWinds' native poller.

Full Access
Question # 10

Which additional polling method is needed after adding an F5 load balancing node for SNMP monitoring?

A.

API

B.

CLI

C.

iControl

D.

WM1

Full Access
Question # 11

Which two of the following best practices are used when creating a universal device poller (UDP)? (Choose two.)

A.

Call SolarWinds support for object ID (OID) options.

B.

Consult vendor documentation for OID.

C.

Perform SNMPwalk to determine if OID exists.

D.

Run WBemtest to test communication to OID.

Full Access
Question # 12

A poller is to be built that will add two values together to show a single value in the web console using the universal device poller (UDP) tool. How would this be accomplished?

A.

add both object IDs (OIDs) to the poller and combine values in a single value for the web console

B.

build a poller for each OID then use transform results to combine values from the two pollers

C.

UDP tool does not support more than one OID per poller, another OID is needed

D.

UDP tool does not support more than one OID per poller, another tool is needed

Full Access
Question # 13

To which port does Log Analyzer forward secure syslog when a log forwarding custom rule action is set to TCP?

A.

161

B.

162

C.

514

D.

6514

Full Access
Question # 14

The below error message is received.

"NetFlow Receiver Service [SERVERNAME] is receiving a NetFlow data stream from an unmanaged device (x.x.x.x). The NetFlow data stream from x.x.x.x will be discarded"

How should this error be resolved?

A.

change the IP address on the node or enable "allow matching nodes by another IP"

B.

ensure the collector service is up

C.

ensure the device is configured to send flow data to hybrid cloud observability (HCO)

D.

only IP flow ingress applied on interfaces

Full Access
Question # 15

A device studio poller is being built for node detail information. For the values supported, it has been decided to enter textual values instead of object IDs (OIDs). Which statement is true?

A.

If the textual value changes, it will update automatically.

B.

If the textual value changes on the node, the poller must be manually updated.

C.

If the textual value is misspelled, it will not poll correctly.

D.

Only textual values can be used for host names, all other values must be OIDs.

Full Access
Question # 16

In live mode, how frequently is log viewer data automatically refreshed?

A.

1 second

B.

10 seconds

C.

1 minute

D.

10 minutes

Full Access