H19-311 Exam Dumps - Huawei Certified Pre-sales Associate- Data Center Facility

Question # 4

Are the air conditioners of the Fusion Mod ule800 connected to the back end of UPSs? ()

A.

Yes

B.

No

Full Access
Question # 5

Which of the following problems shall be considered when selecting the UPS cable? (Multiple Choice)

A.

Rated current of the UPS

B.

Rated operating voltage and insulating voltage of the power cable

C.

Voltage drop of the power cable in the route

D.

Number of the parallel cables

Full Access
Question # 6

What are the subcategories of data center energy in the product directory tree on the SCT configurator homepage? (Multiple Choice)

A.

UPS

B.

Air conditioner

C.

PDC

D.

Modular Data Center

Full Access
Question # 7

The UPS5000-E can realize convenient and simple 2N power supply system only by configuring a ().

A.

BSC cable

B.

Synchronized control

C.

BSC control board

D.

Parallel card

Full Access
Question # 8

The UPS5000-E (50 kVA power module) covers only a small floor area of (), which saves the space in the equipment room.

A.

Im2

B.

1.5 m2

C.

0.8 m2

D.

0.5 m2

Full Access
Question # 9

Which of the following actions does the UPS2000-G take when the main input exceeds the allowable range? ()

A.

Switch to battery mode.

B.

Switch to bypass.

C.

Initiate overvoltage protection or undervoltage protection.

D.

Initiate derating and continue operating.

Full Access
Question # 10

The standard UPS5000-A is equipped with an LCD which supports multiple languages, displays system operating system in real time, and stores a maximum of () alarm records.

A.

2000

B.

2500

C.

3000

Full Access
Question # 11

Which of the following statements is correct about the UPS5000-S at lowloads? (Multiple Choice)

A.

The system efficiency is 95% at 20% loads.

B.

The system efficiency is 96.5% at 20% loads.

C.

The system efficiency is 96% at 40% loads.

D.

The system efficiency is 97% at 40% loads.

Full Access
Question # 12

If the total current of a battery string is 1,000 A and three battery strings are configured, the most economic cable configuration between the main switch box and the branch switch box is ():

A.

95 mm2 (328 A) x2

B.

120 mm2 (382 A) x 2

C.

150 mm2 (441 A) x 2

D.

185 mm2 (506 A) x 1

Full Access
Question # 13

Which of the following are the optional components for the UPS2000-G series (6 kVA to 20 kVA)? () (Multiple Choice)

A.

Temperature and humidity sensor

B.

Battery temperature sensor

C.

Transformer

D.

PDU

Full Access
Question # 14

If the voltage of a single battery in the battery string reaches (), the battery is in the danger state.

A.

1.67 V

B.

2.25 V

C.

2.35 V

D.

2.42 V

Full Access
Question # 15

The UPS5000-E (25-75 kVA) has the industry-leading lightning protection. Its lightning protection level is (), and surge protection level is (). Compared with the other similar UPSs in the industry, it can efficiently reduce the lightning strike failure rate.

A.

5 kA; 6 kV

B.

2kA;4kV

C.

2kA;6kV

D.

4kA;6kV

Full Access
Question # 16

The external maintenance bypass of the UPS typically adopts ()-pole circuit breakers.

A.

1

B.

2

C.

3

D.

4

Full Access
Question # 17

The number of battery strings for the UPS5000-E can be adjusted. To avoid replacing the whole battery string due to one faulty battery and solve the battery maintenance difficulty of traditional UPSs, how many batteries the UPS5000-E (50 kVA power module) can adjust?

A.

30-40

B.

32-40

C.

32-42

D.

30-44

Full Access
Question # 18

The battery voltage of the UPS2000-G is 240 V for the 6-10 kVA capacity models, and is 480 V for the 15 kVA and 20 kVA capacity models.

A.

TRUE

B.

FALSE

Full Access
Question # 19

The number of batteries can be adjusted in the process of UPS configuration.

A.

TRUE

B.

FALSE

Full Access
Question # 20

For the 6-kVA UPS2000-G, a 1+1 parallel system requires () DB15 parallel cables to ensure that each UPS is connected by at least two parallel cables and to enhance the parallel system reliability.

A.

0

B.

1

C.

2

D.

3

Full Access
Question # 21

The built-in SNMP and ModBus card of the UPS5000-A reduce management investment costs for clients.

A.

TRUE

B.

FALSE

Full Access
Question # 22

The UPS5000-A 30-120 kVA can be wall-mounted.

A.

TRUE

B.

FALSE

Full Access
Question # 23

For 80 kW IT loads, configuring an 80 kVA UPS can meet the basic requirements.

A.

TRUE

B.

FALSE

Full Access
Question # 24

The highest temperature in the local area is () when selects T3 air conditioning?

A.

30-35°C

B.

35-43°C

C.

43-55°C

D.

55-65°C

Full Access
Question # 25

The UPS5000-E can realize convenient and simple N+X power supply system only by configuring a ().

A.

BSC cable

B.

Parallel cable

C.

BSC control board

D.

Parallel card

Full Access
Question # 26

The output THDv of the UPS5000-E (50 kVA power module) is (). (Multiple Choice)

A.

Linear full load < 1%

B.

Non-linear full load < 3%

C.

Linear full load < 1.5%

D.

Non-linear full load < 4%

Full Access
Question # 27

The UPS2000-G-20KRTL is rack/tower convertible. The rack-mounted model is () high.

A.

1U

B.

2U

C.

3U

D.

4U

Full Access
Question # 28

The Fusion Mod ule500 adopts free cooling.

A.

TRUE

B.

FALSE

Full Access
Question # 29

The UPS5000-E battery adopts the design without neutral wire, which facilitates battery re-utilization in the replacement of a tower-mounted UPS.

A.

TRUE

B.

FALSE

Full Access
Question # 30

The maximum power of the IT cabinets used by the Fusion Mod ule800 is ()

A.

3kVA

B.

5kVA

C.

7kVA

D.

9kVA

Full Access
Question # 31

The standard components and features in the typical configuration solution of the FusionModule800 include ().

A.

Temperature and humidity sensor, door status sensor, Huawei tablet, water sensor, video surveillance, and mobile app

B.

Smoke sensor, door status sensor, Huawei tablet, water sensor, simple cable trough, and video surveillance

C.

Smoke sensor, temperature and humidity sensor, Huawei tablet, alarm notification over short messages, mobile app, and easy cable trough

Full Access
Question # 32

The UPS5000-A features the design of reliability, high efficiency, and simplicity. Which of the following statements are correct about the UPS5000-A-400/500K? (Multiple Choice)

A.

The UPS5000-A-400/500K has built-in components for parallel operation.

B.

The UPS5000-A-4O0/500K supports the upflow mode.

C.

The UFS5000-A has two control units.

D.

The input voltage of the UPS ranges 138-485 V AC.

Full Access
Question # 33

Compared with the industrial frequency UPS with the SCR, the high frequency UPS with the IGBT rectifier can greatly reduce the input current harmonics and improve the input power factor.

A.

TRUE

B.

FALSE

Full Access