Month End Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

D-PVM-OE-01 Exam Dumps - Dell PowerMax Operate v.2

Go to page:
Question # 25

When using TimeFinder SnapVX, what is the maximum number of linked targets allowed per source?

A.

128

B.

256

C.

512

D.

1024

Full Access
Question # 26

A customer has an existing host with two 100 GB volumes that are assigned from existing PowerMax storage. They would like to add three additional volumes of 100 GB each and change the service level that is assigned to the storage group from Gold to Platinum to support the current application SLO requirements.

Full Access
Question # 27

What are the default settings for a Storage Group in PowerMax, VMAX All Flash, and VMAX3?

A.

No SRP and no SL

B.

Default SRP and no SL

C.

Default SRP and Optimized SL

D.

No SRP and Optimized SL

Full Access
Question # 28

What is the largest TDEV PowerMaxOS 5978 can create?

A.

16 TB

B.

32 TB

C.

64 TB

D.

128 TB

Full Access
Question # 29

A Fibre Channel Host Bus Adapter (HBA) has failed on a host. You have been tasked with replacing the failed adapter.

What is the correct sequence of steps to successfully replace the adapter?

Full Access
Question # 30

A systems administrator asks whether non-disruptive migration (NDM) is supported between their VMAX All Flash arrays. The arrays are located 800 km apart.

What information should be provided to the administrator?

A.

NDM is only supported if the source array is running HYPERMAX OS 5977

B.

NDM is supported between the arrays

C.

NDM is not supported between the arrays

D.

NDM is only supported if the target array is running PowerMax OS 5978

Full Access
Question # 31

What information would you expect to see under the System > Hardware view on a newly installed Unisphere for PowerMax deployment on 2000 and 8000 series arrays?

A.

Capacity, performance, and protection

B.

Provision, protect and set host I/O limits

C.

Front-end director, back-end director, and RDF

D.

10 Profile, performance thresholds, and anomaly detection

Full Access
Question # 32

An administrator is using Unisphere for PowerMax Workload Planner to assess the performance and compliance of a PowerMax Storage Group (SG).

How does the Planner calculate if the Storage Group workload is fully compliant?

A.

Weighted SG average response times for the past 30 minutes

B.

Weighted SG average response time for the past 8 hours and past one week

C.

Weighted SG average response time for the past 4 hours and past two weeks

D.

Weighted SG average response time for the past 4 hours and past one week

Full Access
Go to page: