Labour Day Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

AD01 Exam Dumps - Blue Prism Accredited Developer Exam

Question # 4

The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:

There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New Order screen is in focus?

A)

B)

C)

D)

A.

Exhibit A

B.

Exhibit B

C.

Exhibit C

D.

Exhibit D

Full Access
Question # 5

The main menu of the application Centrix Data Solutions consists of a series of buttons, as displayed below:

When the buttons spied, the element attributes are all identical, with the exception of the Window Text attribute which differs. The Window Text values for each of the buttons displayed above, are ‘HOME’, ‘ORDERS’, ‘CUSTOMER’, ‘STOCK’, ‘INBOX’, ‘SETTINGS’ and ‘EXIT’.

It is described to use a single Dynamic element to interact with each of the menu buttons. The Dynamic button element has been spied and has the following attributes set:

A Navigate stage has been configured to press the ORDERS button:

To ensure the Navigate stage can click the ORDERS button successfully, what additional configuration is required in the Navigate stage?

A.

Update the 'Mouse Button' Inputs value to "ORDERS1

B.

Using the Params button to open the Application Element Parameters window, the Window Text match value must be set to "ORDERS"

C.

A new element is required with the Window Text value set to 'Orders' and the Match Type set to equal

D.

The ORDERS button cannot be clicked using this Dynamic button element, because the Window Text attribute value in Application Modeller is set as EXIT

Full Access
Question # 6

The data item "Loop Counter" is a number data item and has an initial value of 0. The data item "Max Loops" is a number data item and has an initial value of 10.

The two stages are configured as follows:

How many times will the Loop Again stage be executed when the page is executed?

A.

10

B.

9

C.

11

D.

The loop will be infinite

Full Access
Question # 7

What is the Blue Prism Application Navigator

A.

It is the spy tool that you drag around the application to identify attributes.

B.

It is part of the zoom tool in Process and Object Studio that allows you to instantly jump to different parts of the process map

C.

It is the Studio list side-bar of Process and Objects.

D.

It is Application Modeller functionality to create an application's entire element tree that when selected will highlight individual elements in the application.

Full Access
Question # 8

Study the following process flow on the Main Page of a process where the intention is to preserve the current exception.

What is wrong with the design?

A.

The exception handling is not within an Exception Block.

B.

The exception caught by Recover2 will not be preserved by the Re-Throw Exception stage

C.

The Send Alerts process will never be run

D.

Because the flow is on the Main Page of the process there should not be a ‘Re-Throw' Exception stage as there are no parent/calling pages for the exception to bubble up' to.

Full Access
Question # 9

A Blue Prism Process has been developed which contains steps to extract data from a delimited file.

During development, the Developer saves the delimited file to C:\BP_Proc\Temp folder on their virtual desktop and adds a data item to the process to store this file path. This data item is then used in the process steps to extract the file data.

The production Process must read this file from a network folder, and as the Blue Prism production environment is locked down, the Process configuration cannot be edited in this environment.

How could the data item ‘exposure’ be updated, so that the process can read the data item containing the relevant file path, regardless of the environment the process is being executed in?

A.

Update the data item exposure to 'Statistic'

B.

Update the data item exposure to 'Environment'

C.

Update the data item exposure to 'Session'

D.

Update the data item exposure to 'Shared'

Full Access
Question # 10

A process has been created but it is not listed in Control Room. The following reasons have been suggested.

1. The process uses objects with different run modes

2 The process has not been published

3. Process validation shows more than 99 errors

4. The user does not have privileges to run processes in Control Room?

Which of the above could cause the process not to be visible in Control Room?

A.

1 and 2

B.

2 only

C.

2 and 3

D.

1 and 4

Full Access
Question # 11

Consider the following flow in an object:

Which of the following statements are true?

A.

There just needs to be a wait stage after the start stage to correct this action.

B.

There should be a wait stage after every stage in this flow (i.e. after the navigate, read, write stages.

C.

If during testing in object studio this flow works, no additional wait stages should be added as they will slow the interface down.

D.

There should be an intelligent wait stage after the start stage and after any stage that cause the application we are interfacing with to change

Full Access
Question # 12

When automating a Windows application what type of stage is configured to perform a Global Send Key Events?

A.

Notes Stage

B.

Read Stage

C.

Write Stage

D.

Navigate Stage

Full Access
Question # 13

Examine the flow below:

An error has been encountered on Page 1 and the exception has bubbled up to be recovered in the Recoverd stage The Yes' path has been taken from the "Throw new Exception?" decision stage. Consider the Throw Exception stage properties below:

How should the properties be configured for the Process to throw a new Business exception, i.e. a different exception to the one encountered in Page?

A.

Configure ExceptionType() in the Exception Type field and ExceptionDetail() in the Exception Detail field. Leave the Preserve the type and detail of the current exception checkbox un-ticked.

B.

Tick the Preserve the type and detail of the current exception checkbox. Leave the Exception Type and Exception Detail fields blank

C.

Leave the Exception Type field blank and type "Business Exception" in the Exception Detail field.

D.

Type Business Exception in the Exception Type field and type a custom message in the Exception Detail field.

Full Access
Question # 14

Which of the statements below best describes what Blue Prism is used for?

A.

Blue Prism is used for modelling business processes

B.

Blue Prism is used to link core business applications together

C.

Blue Prism is used to create Virtual Digital Workers that can replicate user actions and decisions

D.

Blue Prism is used to transfer data from one system to another

Full Access
Question # 15

FILL BLANK

Examine the following recover flow taken from a Blue Prism Process:

The ‘Exception Detail’ data item has no initial value and has a data type of text.

The Calculation stage ‘Save Exception Detail’ will output the current exception detail to the ‘Exception Detail’ data item.

What expression would you use in the ‘Save Exception Detail’ stage to achieve this?

Full Access