The Order System application has been successfully launched and Blue Prism has navigated the application to the following screen:
There is a requirement to ensure this screen is in focus before any further interfacing is done with the screen. Which is the correct configuration to ensure the New Order screen is in focus?
A)
B)
C)
D)
The main menu of the application Centrix Data Solutions consists of a series of buttons, as displayed below:
When the buttons spied, the element attributes are all identical, with the exception of the Window Text attribute which differs. The Window Text values for each of the buttons displayed above, are ‘HOME’, ‘ORDERS’, ‘CUSTOMER’, ‘STOCK’, ‘INBOX’, ‘SETTINGS’ and ‘EXIT’.
It is described to use a single Dynamic element to interact with each of the menu buttons. The Dynamic button element has been spied and has the following attributes set:
A Navigate stage has been configured to press the ORDERS button:
To ensure the Navigate stage can click the ORDERS button successfully, what additional configuration is required in the Navigate stage?
The data item "Loop Counter" is a number data item and has an initial value of 0. The data item "Max Loops" is a number data item and has an initial value of 10.
The two stages are configured as follows:
How many times will the Loop Again stage be executed when the page is executed?
Study the following process flow on the Main Page of a process where the intention is to preserve the current exception.
What is wrong with the design?
A Blue Prism Process has been developed which contains steps to extract data from a delimited file.
During development, the Developer saves the delimited file to C:\BP_Proc\Temp folder on their virtual desktop and adds a data item to the process to store this file path. This data item is then used in the process steps to extract the file data.
The production Process must read this file from a network folder, and as the Blue Prism production environment is locked down, the Process configuration cannot be edited in this environment.
How could the data item ‘exposure’ be updated, so that the process can read the data item containing the relevant file path, regardless of the environment the process is being executed in?
A process has been created but it is not listed in Control Room. The following reasons have been suggested.
1. The process uses objects with different run modes
2 The process has not been published
3. Process validation shows more than 99 errors
4. The user does not have privileges to run processes in Control Room?
Which of the above could cause the process not to be visible in Control Room?
Consider the following flow in an object:
Which of the following statements are true?
When automating a Windows application what type of stage is configured to perform a Global Send Key Events?
Examine the flow below:
An error has been encountered on Page 1 and the exception has bubbled up to be recovered in the Recoverd stage The Yes' path has been taken from the "Throw new Exception?" decision stage. Consider the Throw Exception stage properties below:
How should the properties be configured for the Process to throw a new Business exception, i.e. a different exception to the one encountered in Page?
FILL BLANK
Examine the following recover flow taken from a Blue Prism Process:
The ‘Exception Detail’ data item has no initial value and has a data type of text.
The Calculation stage ‘Save Exception Detail’ will output the current exception detail to the ‘Exception Detail’ data item.
What expression would you use in the ‘Save Exception Detail’ stage to achieve this?