Labour Day Sale Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

5V0-22.23 Exam Dumps - VMware vSAN Specialist (v2)

Question # 4

A customer wishes to host a new range of applications with high-performance requirements, specifically, low latency. The current vSAN platform is based on ReadyNode hardware and uses a vSAN 7.0 U2 hybrid topology configuration.

Which would satisfy the customer's requirement?

A.

Deploy the application on a new cluster with vSAN 8.0 ESA using a new hardware design

B.

Deploy the new applications on the existing cluster with a RAID-6 VM storage policy and an additional stripe width of 4

C.

Deploy the application on a new cluster with vSAN 8.0 OSA using the existing hybrid configuration

D.

Perform an in-place upgrade from vSAN 7.0 U2 OSA to vSAN 8.0 ESA

Full Access
Question # 5

How often does the Skyline Health interval validate online if there are new Health Checks available for vSAN?

A.

Every 1 hour

B.

Every 4 hours

C.

Every 24 hours

D.

Every 12 hours

Full Access
Question # 6

A vSAN administrator has an existing cluster where each ESXi host has the following:

Disk group #1 with one cache device and three capacity devices.

Disk group #2 with one cache device and two capacity devices.

What must the vSAN administrator do to expand disk group #2 to have three capacity devices?

A.

Create a new disk group with a single capacity device and then migrate the existing capacity devices

B.

Add the new capacity device to the disk group and vSAN will automatically rebalance

C.

Put the entire ESXi host in maintenance mode, evacuate all data, then add the new capacity device

D.

Put the disk group in maintenance mode, evacuate all data, then add the new capacity device

Full Access
Question # 7

What is the purpose of the TRIM/UNMAP process?

A.

Collects vSAN log files

B.

Repairs internal cache errors

C.

Deletes orphaned snapshots

D.

Reclaims disk space

Full Access
Question # 8

All of the virtual machines running on a hybrid vSAN datastore have this storage policy assigned:

Failures to Tolerate (FTT) rule is set to "2 Failures - RAID-1 (Mirroring)"

The vSAN administrator needs to reduce the amount of vSAN datastore capacity the virtual machines will consume.

Which action should the vSAN administrator take to meet this goal?

A.

Modify the FTT rule to "2 Failures - RAID-5 (Erasure Coding)"

B.

Add the "Flash read cache reservation" rule to the storage policy, and set to 0%

C.

Disable Operations reserve and Host rebuild reserve and click "Apply"

D.

Change the FTT rule to "1 Failure - RAID-1 (Mirroring)", and select "Now" for Reapply to VMs

Full Access
Question # 9

A customer wants to validate if Skyline online health is working for vSAN and finds out that Skyline is not fully configured yet.

What two requirements must be met to make sure that Skyline online health will work? (Choose two.)

A.

Add the Skyline license into Virtual Center

B.

Enable Skyline Health on the vSAN Cluster

C.

Enable CEIP and join the program

D.

Have a working Internet connection

E.

Have vCenter on version 7 or higher

Full Access
Question # 10

An administrator wants to assign a storage policy to a workload on a two-node vSAN OSA cluster consisting of three disk groups each with nested fault domains. The virtual machine must be protected against a disk or disk group failure.

Which two storage policies meet these requirements? (Choose two.)

A.

RAID-5/FTT 2

B.

RAID-1/FTT 3

C.

RAID-6/FTT 2

D.

RAID-5/FTT 1

E.

RAID-1/FTT 1

Full Access
Question # 11

An administrator wishes to prevent vCenter notifications of vSAN Health status during a scheduled maintenance window.

Which action can be taken to achieve this goal?

A.

Disable the performance service

B.

Disable the alarm from the HTML client

C.

Run performance diagnostics prior to scheduled maintenance

D.

Disable SNMP service

Full Access
Question # 12

An all-flash vSAN ESA cluster contains four nodes.

Which two storage policies can the cluster satisfy? (Choose two.)

A.

FTT=3 (RAID-1 Mirroring)

B.

FTT=2 (RAID-1 Mirroring)

C.

FTT=I (RAID-5 Erasure Coding)

D.

FTT=I (RAID-1 Mirroring)

E.

FTT=2 (RAID-6 Erasure Coding)

Full Access
Question # 13

A vSAN administrator notices that the VMware Skyline Health: Network Latency Check reports indicate that three hosts are noncompliant.

Which action should the vSAN administrator take?

A.

Immediately reboot the non-compliant hosts

B.

Check VMKNICs, uplinks, physical switches, and associated settings

C.

Rerun the VMware Skyline Health: vSAN Cluster Partition report

D.

Place the non-compliant hosts into an isolated network partition

Full Access
Question # 14

A six-node vSAN ESA cluster contains multiple virtual machines, and a vSAN storage policy with the rule "Failures to tolerate" set to "1 failure - RAID-5 (Erasure Coding)" is assigned. A vSAN administrator has changed the rule in the assigned policy to "2 failures - RAID-6 (Erasure Coding)".

What is the result of this change?

A.

No changes occur until the policy is reapplied.

B.

The changes are queued for 60 minutes.

C.

The policy change is rejected immediately.

D.

The updated policy is serially applied to the virtual machines.

Full Access
Question # 15

Which VMware solution requires vSAN usage?

A.

VMware Cloud Foundation

B.

VMware Horizon

C.

VMware Telco Cloud Automation

D.

VMware Aria Automation

Full Access
Question # 16

When adding a disk to a host that was previously used in a decommissioned vSAN cluster the intended disk does not show among the available devices in disk management.

Which action should be taken prior to assigning the disk on disk management?

A.

Format the existing partition

B.

Create a 1GB metadata partition

C.

Delete all device partitions

D.

Create a VMFS partition

Full Access
Question # 17

A customer has deployed a new vSAN cluster with the following configuration:

5 x vSAN ReadyNodes

All Flash

12 TB Raw Storage

vSAN 8 is deployed with ESA.

New VMs are configured with a RAID-5 VM policy.

Which statement is accurate?

A.

vSAN will use a 2+1 RAID-5 data placement scheme with parity will be used

B.

RAID 5 will provide an FTT=2 level of protection in this case

C.

vSAN will use a 4+1 RAID-5 data placement scheme with parity will be used

D.

vSAN will spread the components across all of the disk groups

Full Access
Question # 18

A vSAN administrator has two identical VMware vSAN clusters, one for staging workloads and another for production workloads. Due to an unforeseen capacity requirement, the vSAN administrator is tasked with merging the staging vSAN cluster into the production.

Which three actions should the vSAN administrator perform on the staging cluster prior to moving the vSAN nodes to the production cluster? (Choose three.)

A.

Disable vSAN Services

B.

Delete all Disk Groups

C.

Enable File Services

D.

Delete all partitions from the capacity disks

E.

Mark the disks for partial reservation

F.

Remove all capacity drives

Full Access
Question # 19

A vSAN administrator is responsible for managing a customer's production vSAN cluster that is going to be used to provide SMB file shares to a number of host clients. The vSAN administrator must take action so the performance of all services in the production vSAN cluster can be monitored.

Which two services must be enabled for this monitoring to occur? (Choose two.)

A.

vSAN Performance Diagnostic Service

B.

iSCSI Target Service

C.

vSAN File Services

D.

vSAN Health Service

E.

vSAN Performance Service

Full Access
Question # 20

A vSAN administrator is planning to deploy a new vSAN cluster with these requirements:

Physical adapters share capacity among several traffic types

Guaranteed bandwidth for vSAN during bandwidth contention

Enhanced security

Which two actions should be taken to configure the new vSAN cluster to meet these requirements? (Choose two.)

A.

Create static routes between the vSAN hosts

B.

Use IOPS Limit rules in storaqe policies

C.

Utilize Network I/O Control

D.

Enable jumbo frames

E.

Isolate vSAN traffic in a VLAN

Full Access
Question # 21

A vSAN administrator was presented with 30 additional vSAN ReadyNodes to add to an existing vSAN cluster. There is only one administrator to complete this task.

What is the fastest approach?

A.

Run vim-cmd to capture, and apply the configuration from an existing host

B.

Launch Quickstart to Add Hosts to a vSAN Cluster

C.

Clone the ESXi boot partition to all new hosts, since the hardware is identical

D.

Use a Host Profile that was extracted from an existing host

Full Access