Spring Sale Special Limited Time 70% Discount Offer - Ends in 0d 00h 00m 00s - Coupon code: scxmas70

M2 Exam Dumps - Commercial Mechanical Inspector

Searching for workable clues to ace the International Code Council M2 Exam? You’re on the right place! ExamCert has realistic, trusted and authentic exam prep tools to help you achieve your desired credential. ExamCert’s M2 PDF Study Guide, Testing Engine and Exam Dumps follow a reliable exam preparation strategy, providing you the most relevant and updated study material that is crafted in an easy to learn format of questions and answers. ExamCert’s study tools aim at simplifying all complex and confusing concepts of the exam and introduce you to the real exam scenario and practice it with the help of its testing engine and real exam dumps

Go to page:
Question # 9

Natural, manufactured and liquefied petroleum, or a mixture of these, make up:

A.

fuel oil.

B.

fuel gas.

C.

natural gas.

D.

liquefied petroleum gas.

Full Access
Question # 10

Shutoff valves in plastic pipe ground-source heat pump loop systems shall be installed on both sides of which one of the following?

A.

Expansion tanks

B.

Heat-fusion joints

C.

Change-in-material joints

D.

Pressure-reducing valves

Full Access
Question # 11

Solid-fuel cooking equipment:

A.

shall be vented through a separate hood and exhaust system.

B.

is permitted to be installed under Type II canopy-type hoods.

C.

is permitted to be installed under Type II noncanopy-type hoods.

D.

is permitted to be installed under common canopy-type hoods with other cooking equipment.

Full Access
Question # 12

The optional integral clearance reduction system is designed to meet which NFPA standard?

A.

33

B.

72

C.

92A

D.

96

Full Access
Question # 13

Where the cooking surface has exposed flame and burners, the minimum distance between the lowest edge of a grease filter and the cooking or heating surface shall be _____ inches.

A.

18

B.

24

C.

42

D.

48

Full Access
Question # 14

What is the minimum air velocity that must be provided by an exhaust duct system serving a Type I range hood?

A.

500 FPM

B.

500 CFM

C.

1,500 FPM

D.

2,500 FPM

Full Access
Question # 15

For the installation of listed fuel-burning appliances, the required clearances should be found:

A.

in the mechanical code.

B.

on the nameplate of the appliance.

C.

on the approved plans and specifications for the building.

D.

by using a calculation based on the Btu/h output rating of the appliance.

Full Access
Go to page: