Exact Extract — Huawei HCSA-Presales-Data Center Facility (Modular DC) V1.0 Training Material, PDF page 53
“Detailed introduction of 4 basic configurations Power type 220/230/240V, 50/60Hz, 1Ph+N+PE 208V-2Ph+PE-60Hz Basic BC1L BC2L BC3L BC4L(Latin America) configuration Aisle type NO Cold and hot aisle containment UPS(KVA) 6 10 6 6 Cooling NO Integrated cooling Power input Single Single rPDU 1ã€2 (optional) 1ã€2 (optional) 2*40A/1P+2*40A/2P+1*32A/ IT output 5(4*40A+1*16A) 2*40A/1P+3*16A/1P 2P Smoke sensor, T & H sensor, Smoke sensor, T & H sensor, Standard intelligent lock, 10-inch PAD, intelligent lock, 10-inch PAD, Smoke sensor, T & H sensor, SMS/email alarm Configuration SMS/email alarm*, and local SMS/email alarm*, and local app O & M app O & M Fire extinguishing module, Fire extinguishing module, video surveillance, water Home A/C restart function, video surveillance, water video surveillance, water Optional leakage sensor, and mobile leakage sensor, door sensor, and mobile O & Mâ€
Technical Deep Dive
The rack-mounted fire-extinguishing module is 43.6 mm high, equivalent to 1U, and uses perfluorohexanone as its extinguishing agent.
The compact rack-mounted fire-extinguishing unit uses perfluorohexanone, commonly identified as FK-5-1-12 or Novec 1230, and occupies approximately one rack unit of height. The fire-extinguishing module is optional rather than fitted to every FusionModule500. Local agent discharge and detection linkage must be engineered for the protected enclosure and the applicable fire standards. Equipment selection should distinguish the optional protection module from the standard monitoring components.
The FusionModule500 family contains cooled and noncooled configurations with different IT power limits. The selected UPS, room cooling conditions, battery runtime and enclosure arrangement must be checked together. A rating for a particular BC configuration must not be presented as the maximum or standard feature of every FusionModule500 installation.
Verification principle: confirm the exact product revision, operating condition, selected option and relevant Huawei documentation before using this result in a customer proposal. A feature shown for a particular configuration should not automatically be assumed to apply to every module or installation; normal technical, commercial and safety checks still apply.
Technical verification warning: The 1U perfluorohexanone extinguisher is optional; it is not installed in every FusionModule500.
Source reference: uploaded Huawei training material, PDF page 53.